Skip to Main Content (Press Enter)

Logo UNIECAMPUS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

UNI-FIND
Logo UNIECAMPUS

|

UNI-FIND

uniecampus.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

An accelerometer-based single-arm dynamic stability test for the assessment of the sensorimotor control of the shoulder

Articolo
Data di Pubblicazione:
2026
Abstract:
The study aimed at designing and validating a variation of the Single-Arm Dynamic Stability test as performed in Open Kinetic Chain for assessing the shoulder's sensorimotor control with the subject lying supine while holding a dumbbell still in one hand with the extended arm. The dumbbell's sway, monitored via a triaxial accelerometer, was modelled as an inverted pendulum pivoted at shoulder level. Twenty college students performed bilateral tests for 30 s using loads of 15 %, 25 %, and 35 % of a reference load determined as the mass measured by a scale placed under the hands during a quadruped position. The test was repeated 30 min and 24 h later. Time- and frequency-domain stabilometric parameters were computed using both the entire 30 s test duration and the first 20 s. ICC analysis revealed that the test as performed at 15 % of the reference load exhibited the highest intra- and inter-day reliability for both sides and durations, while reliability decreased at higher loads. Specifically, Jerk and swayArea exhibited good-to-excellent intra-day reliability (ICC = 0.866–0.947) and moderate-to-good inter-day reliability (ICC = 0.707–0.766), with 30 s test duration. All other stabilometric parameters showed moderate or moderate-to-good reliability (ICC > 0.5). The test provides a reliable, accessible, and ecologically valid assessment of shoulder sensorimotor control, with potential applications in clinical settings.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Accelerometry; Field test; Inertial sensors; Kinesiology; Neuromuscular control; Shoulder stability; Sway assessment
Elenco autori:
Picerno, Pietro; Iuliano, Enzo; Bravi, Marco; Santacaterina, Fabio; Ramos, Amador García; Pešović, Uroš; Méndez, Rigoberto Martínez; Vieira, Taian Martins
Autori di Ateneo:
IULIANO ENZO
PICERNO PIETRO
Link alla scheda completa:
https://iris.uniecampus.it/handle/11389/88975
Pubblicato in:
JOURNAL OF BIOMECHANICS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.0.0