Skip to Main Content (Press Enter)

Logo UNIECAMPUS
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  • Equipment

UNI-FIND
Logo UNIECAMPUS

|

UNI-FIND

uniecampus.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  • Equipment
  1. Outputs

Detection of hearing losses (HL) via transient-evoked otoacoustic emissions: towards an automatic classification

Academic Article
Publication Date:
2022
abstract:
Transiently evoked otoacoustic emissions (TEOAEs) are routinely used in the hearing assessment of the auditory periphery. The major contribution of TEOAEs is the early detection of hearing losses in neonates, children, and adults. The evaluation of TEOAE responses by specific signal decomposition techniques offers numerous advantages for current and future research. One methodology, based on recurrence quantification analysis (RQA), can identify adult subjects presenting sensorineural hearing impairments. In two previous papers, the RQA-based approach was succesfully applied in identifying and classifying cases presenting noise and age related hearing losses. The current work investigates further two aspects of the previously proposed RQA-based analysis for hearing loss detection: (i) the reliability of a Training set built from different numbers of ears with normal hearing, and (ii) the threshold set of values of the key hearing loss detecting parameter RAD2D. Results: The Training set built from 158 healthy ears was found to be quite reliable and a similar but slightly minor performance was observed for the training set of 118 normal subjects, used in the past; the proposed ROC-curve method, optimizing the values of RAD2D, shows improved sensibility and specificity in one class discrimination. Conclusions: A complete and simplified procedure, based on the combined use of the traditional TEOAE reproducibility value and on values from the RQA-based RAD2D parameter, is proposed as an improved automatic classifier, in terms of sensitivity and specificity, for different types of hearing losses.
Iris type:
1.1 Articolo in rivista
Keywords:
TEOAE, hearing losses discrimination, RQA, complexity, ROC
List of contributors:
Zimatore, Giovanna; Cavagnaro, Marta; H Skarzynski, Piotr; Stavros Hatzopoulos, And
Authors of the University:
ZIMATORE GIOVANNA
Handle:
https://iris.uniecampus.it/handle/11389/37880
Published in:
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS
Journal
  • Overview

Overview

URL

https://doi.org/10.1088/20571976/ac7a5e
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.11.0.1