Skip to Main Content (Press Enter)

Logo UNIECAMPUS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

UNI-FIND
Logo UNIECAMPUS

|

UNI-FIND

uniecampus.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Bioimpedancemetry for the assessment of periodontal tissue inflammation: a numerical feasibility study

Articolo
Data di Pubblicazione:
2017
Abstract:
In dentistry possible inflammatory episodes of oral cavity can be very frequent (periodontitis, mucositis, peri-implantitis) and they can have serious consequences. Indeed, peri-implantitis is still the principal cause of implant failure. Impedance values of biological tissues are related to the physiological/pathological state of the tissue itself. In fact, an inflamed site exhibits an impedance value lower than that of the corresponding healthy tissue. Based on these observations, the aim of this work is to determine if impedancemetric measurements are able to provide information about the inflammatory state of tissues. A numerical 3D model has been realized to simulate the measurement conditions present in the event of inflammation around a dental implant. The aim is to understand if it is possible to determine the presence of an inflamed tissue and to locate its site, so that the treatment could be specifically focused in that specific area. A simplified geometry reproducing the implant has been realized in order to validate the numerical model by means of experimental measurements. The obtained results are satisfactorily accurate, so the model can be considered reliable. Therefore, multiple simulations have been run on the original model to carry out a parametric study in terms of different conductivity values, different volumes of inflamed tissues and different measurement frequencies. The advantages and limits of such a method have been shown to properly define the main constraints for the system design.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Inflammation; impedance; alternating current (AC); numerical simulation; dentistry; human tooth
Elenco autori:
Cosoli, Gloria; Scalise, Lorenzo; Cerri, Graziano; Russo, Paola; Tricarico, Gerardo; Tomasini, Enrico Primo
Autori di Ateneo:
COSOLI GLORIA
Link alla scheda completa:
https://iris.uniecampus.it/handle/11389/58316
Pubblicato in:
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING
Journal
  • Dati Generali

Dati Generali

URL

http://www.tandfonline.com/eprint/uubSakNhptJcjUPixCTW/full
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0